    Thermokoz | Pel (without ash removal)
    Pelet

    Pel (without ash removal)

    PEL is a safe pellet boiler that eliminates the risk of backfiring thanks to its step loading system.


    With its high-efficiency body that can burn 6-8-10 mm pellets, it provides maximum heating performance.


    It is a user-friendly, reliable, and efficient heating solution with advanced mechanical and electronic features.

    Color Option

    Thermokoz | Pel (without ash removal) Red

    Our product provides economy with its high-efficiency body design.


    It offers comfort to the user with its rich functions such as automatic loading, automatic mixing, automatic ignition system, etc.

    Whatsapp Support

    General Features

    Technical Specifications

    Documents

    Images & Videos

    Thermokoz | Pel (without ash removal)
    By rotating the auger with the help of the electronic fuel supply motor It offers the possibility of ‘Automatic Refuelling’. In this way, both from your place You can warm up without getting up and with balanced fuel consumption.

    Automatic Refuelling

    Thermokoz | Pel (without ash removal)
    Of course, you do not need to ignite the loaded fuel with your hand. Device fuelling level automatically according to the temperature value you set. will load, then it will take as little as 5 minutes to get it working. in which the ignition will be carried out automatically.

    Automatic Ignition

    Thermokoz | Pel (without ash removal)
    Automatic Mixing Our featured hob, 100% efficient combustion provides. Thanks to its innovative design, a powerful and effective warm-up at all times minimises energy losses. High efficiency, maximum Stay one step ahead for performance now!

    Automatic Mixing

    Thermokoz | Pel (without ash removal)
    With the boiler sensor and boiler pump start-up feature, your boiler is now guaranteed to produce hot water in summer and winter! Warm all year round, in all seasons This smart system, which meets your water needs, offers energy efficiency and superior makes your life easier with its performance. Always enjoy hot water Take it out, don't compromise on your comfort!

    Boiler Integration

    Thermokoz | Pel (without ash removal)
    What about the electronic board that controls all this equipment? wirelessly control the device, you can control the device fully automatically. manage and set up a weekly programme and automatic work schedule you can create.

    Remote Control

    Thermokoz | Pel (without ash removal)
    By rotating the auger with the help of the electronic fuel supply motor It offers the possibility of ‘Automatic Refuelling’. In this way, both from your place You can warm up without getting up and with balanced fuel consumption.

    Automatic Refuelling

    Thermokoz | Pel (without ash removal)
    Of course, you do not need to ignite the loaded fuel with your hand. Device fuelling level automatically according to the temperature value you set. will load, then it will take as little as 5 minutes to get it working. in which the ignition will be carried out automatically.

    Automatic Ignition

    Thermokoz | Pel (without ash removal)
    Automatic Mixing Our featured hob, 100% efficient combustion provides. Thanks to its innovative design, a powerful and effective warm-up at all times minimises energy losses. High efficiency, maximum Stay one step ahead for performance now!

    Automatic Mixing

    Thermokoz | Pel (without ash removal)
    With the boiler sensor and boiler pump start-up feature, your boiler is now guaranteed to produce hot water in summer and winter! Warm all year round, in all seasons This smart system, which meets your water needs, offers energy efficiency and superior makes your life easier with its performance. Always enjoy hot water Take it out, don't compromise on your comfort!

    Boiler Integration

    Thermokoz | Pel (without ash removal)
    What about the electronic board that controls all this equipment? wirelessly control the device, you can control the device fully automatically. manage and set up a weekly programme and automatic work schedule you can create.

    Remote Control

    Thermokoz | Pel (without ash removal)
    By rotating the auger with the help of the electronic fuel supply motor It offers the possibility of ‘Automatic Refuelling’. In this way, both from your place You can warm up without getting up and with balanced fuel consumption.

    Automatic Refuelling

    Thermokoz | Pel (without ash removal)
    Of course, you do not need to ignite the loaded fuel with your hand. Device fuelling level automatically according to the temperature value you set. will load, then it will take as little as 5 minutes to get it working. in which the ignition will be carried out automatically.

    Automatic Ignition

    Thermokoz | Pel (without ash removal)
    Automatic Mixing Our featured hob, 100% efficient combustion provides. Thanks to its innovative design, a powerful and effective warm-up at all times minimises energy losses. High efficiency, maximum Stay one step ahead for performance now!

    Automatic Mixing

    Thermokoz | Pel (without ash removal)
    With the boiler sensor and boiler pump start-up feature, your boiler is now guaranteed to produce hot water in summer and winter! Warm all year round, in all seasons This smart system, which meets your water needs, offers energy efficiency and superior makes your life easier with its performance. Always enjoy hot water Take it out, don't compromise on your comfort!

    Boiler Integration

    Thermokoz | Pel (without ash removal)
    What about the electronic board that controls all this equipment? wirelessly control the device, you can control the device fully automatically. manage and set up a weekly programme and automatic work schedule you can create.

    Remote Control

    Thermokoz | Pel (without ash removal)
    MODEL
    Capacity kW 150
    Width (A) mm 1950
    Length (B) mm 2000
    Height (C) mm 1600
    Cold Water Inlet Height (D) mm 530
    Hot Water Outlet Height (E) mm 1600
    Chimney Exit Height (F) mm 1260
    Chimney Diameter mm 250
    Flow – Return inches 2 1/2
    Drain Exit inches 1 1/2
    Fill – Empty inches 1/2
    Weight kg 960
    Water Capacity liters 350
    Chamber Capacity liters 230
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 180
    Fan Power W 105
    Ash Bin Capacity liters 95
    Operating Voltage and Frequency V/Hz 230/50
    Operating Current A 16
    Capacity kW 174
    Width (A) mm 2300
    Length (B) mm 2100
    Height (C) mm 1900
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 1900
    Chimney Exit Height (F) mm 1450
    Chimney Diameter mm 300
    Flow – Return inches 2 1/2
    Drain Exit inches 1 1/2
    Fill – Empty inches 1
    Weight kg 1540
    Water Capacity liters 470
    Chamber Capacity liters 450
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 2×105
    Ash Bin Capacity liters 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 209
    Width (A) mm 2300
    Length (B) mm 2100
    Height (C) mm 2000
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 2000
    Chimney Exit Height (F) mm 1400
    Chimney Diameter mm 300
    Flow – Return inches 2 1/2
    Drain Exit inches 1 1/2
    Fill – Empty inches 1
    Weight kg 1600
    Water Capacity liters 520
    Chamber Capacity liters 450
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 2×105
    Ash Bin Capacity liters 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 232
    Width (A) mm 2300
    Length (B) mm 2250
    Height (C) mm 2000
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 2000
    Chimney Exit Height (F) mm 1400
    Chimney Diameter mm 300
    Flow – Return inches 2 1/2
    Drain Exit inches 1 1/2
    Fill – Empty inches 1
    Weight kg 1715
    Water Capacity liters 585
    Chamber Capacity liters 450
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 2×105
    Ash Bin Capacity liters 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 290
    Width (A) mm 2450
    Length (B) mm 2300
    Height (C) mm 2200
    Cold Water Inlet Height (D) mm 650
    Hot Water Outlet Height (E) mm 2200
    Chimney Exit Height (F) mm 1600
    Chimney Diameter mm 300
    Flow – Return inches 2 1/2
    Drain Exit inches 1 1/2
    Fill – Empty inches 1
    Weight kg 2080
    Water Capacity liters 1050
    Chamber Capacity liters 600
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 2×105
    Ash Bin Capacity liters 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 348
    Width (A) mm 2500
    Length (B) mm 2850
    Height (C) mm 2250
    Cold Water Inlet Height (D) mm 720
    Hot Water Outlet Height (E) mm 2250
    Chimney Exit Height (F) mm 1750
    Chimney Diameter mm 400
    Flow – Return inches 3
    Drain Exit inches 2
    Fill – Empty inches 2
    Weight kg 3000
    Water Capacity liters 1350
    Chamber Capacity liters 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 2×240
    Ash Bin Capacity liters 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 465
    Width (A) mm 2560
    Length (B) mm 3250
    Height (C) mm 2250
    Cold Water Inlet Height (D) mm 720
    Hot Water Outlet Height (E) mm 2250
    Chimney Exit Height (F) mm 1750
    Chimney Diameter mm 400
    Flow – Return inches 3
    Drain Exit inches 2
    Fill – Empty inches 2
    Weight kg 3500
    Water Capacity liters 1750
    Chamber Capacity liters 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 2×240
    Ash Bin Capacity liters 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 581
    Width (A) mm 2800
    Length (B) mm 3550
    Height (C) mm 2550
    Cold Water Inlet Height (D) mm 730
    Hot Water Outlet Height (E) mm 2550
    Chimney Exit Height (F) mm 1950
    Chimney Diameter mm 500
    Flow – Return inches 4
    Drain Exit inches 2
    Fill – Empty inches 2
    Weight kg 4000
    Water Capacity liters 2500
    Chamber Capacity liters 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 3×240
    Ash Bin Capacity liters 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 697
    Width (A) mm 2800
    Length (B) mm 4050
    Height (C) mm 2550
    Cold Water Inlet Height (D) mm 730
    Hot Water Outlet Height (E) mm 2550
    Chimney Exit Height (F) mm 1950
    Chimney Diameter mm 500
    Flow – Return inches 4
    Drain Exit inches 2
    Fill – Empty inches 2
    Weight kg 5550
    Water Capacity liters 3100
    Chamber Capacity liters 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 3×240
    Ash Bin Capacity liters 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 814
    Width (A) mm 3500
    Length (B) mm 4000
    Height (C) mm 2800
    Cold Water Inlet Height (D) mm 750
    Hot Water Outlet Height (E) mm 2750
    Chimney Exit Height (F) mm 2250
    Chimney Diameter mm 600
    Flow – Return inches 5
    Drain Exit inches 2 1/2
    Fill – Empty inches 2 1/2
    Weight kg 6000
    Water Capacity liters 3500
    Chamber Capacity liters 1600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 3×240
    Ash Bin Capacity liters 200
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 930
    Width (A) mm 3500
    Length (B) mm 4250
    Height (C) mm 2800
    Cold Water Inlet Height (D) mm 750
    Hot Water Outlet Height (E) mm 2800
    Chimney Exit Height (F) mm 2250
    Chimney Diameter mm 600
    Flow – Return inches 5
    Drain Exit inches 2 1/2
    Fill – Empty inches 2 1/2
    Weight kg 6770
    Water Capacity liters 3900
    Chamber Capacity liters 1600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 3×240
    Ash Bin Capacity liters 200
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 1160
    Width (A) mm 3500
    Length (B) mm 4500
    Height (C) mm 3000
    Cold Water Inlet Height (D) mm 800
    Hot Water Outlet Height (E) mm 3000
    Chimney Exit Height (F) mm 2350
    Chimney Diameter mm 600
    Flow – Return inches 5
    Drain Exit inches 2 1/2
    Fill – Empty inches 2 1/2
    Weight kg 7500
    Water Capacity liters 4800
    Chamber Capacity liters 1600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 3×240
    Ash Bin Capacity liters 200
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Thermokoz | Pel (without ash removal) PDF
    Technical Drawing