OFFER FORM

You can send us your suggestions, complaints and requests for products via the form below.

    CAPACITY CALCULATION

    With our capacity calculation application, you can calculate your heat capacity in accordance with the values you have entered.

    BUILDING AREA (M²)
    CEILING HEIGHT (MT)
    BUILDING LOCATION
    BUILDING LOCATION

    *The heat capacities calculated according to the values you have entered are given as completely estimated information and Kozlusan does not guarantee the accuracy of these values at any time.

    *For the most accurate information, please contact one of our nearest authorized dealers or installation engineering companies.

    Thermokoz | Pel (Ash Sticker)
    Pelet

    Pel (Ash Sticker)

    PEL is a safe pellet boiler that eliminates the risk of backfire thanks to its step-loading system.

    Its high-efficiency body, capable of burning 6-8-10 mm pellets, provides maximum heating performance.

    With its advanced mechanical and electronic features, it is a user-friendly, reliable, and efficient heating solution.

    Color Option

    Thermokoz | Pel (Ash Sticker) Kırmızı

    Our product provides economic benefits with its high-efficiency body design.
    Automatic loading,
    automatic ash removal, automatic mixing, automatic ignition system, and other rich
    features offer comfort to the user.

    Whatsapp Support

    General Features

    Technical Specifications

    Documents

    Images & Videos

    Thermokoz | Pel (Ash Sticker)
    By rotating the auger with the help of the electronic fuel supply motor It offers the possibility of ‘Automatic Refuelling’. In this way, both from your place You can warm up without getting up and with balanced fuel consumption.

    Automatic Refuelling

    Thermokoz | Pel (Ash Sticker)
    Of course, you do not need to ignite the loaded fuel with your hand. Device fuelling level automatically according to the temperature value you set. will load, then it will take as little as 5 minutes to get it working. in which the ignition will be carried out automatically.

    Automatic Ignition

    Thermokoz | Pel (Ash Sticker)
    Automatic Mixing Our featured hob, 100% efficient combustion provides. Thanks to its innovative design, a powerful and effective warm-up at all times minimises energy losses. High efficiency, maximum Stay one step ahead for performance now!

    Automatic Mixing

    Thermokoz | Pel (Ash Sticker)
    Where does the waste from all these cleared areas go? That's where the answer is given by the ‘Automatic Ash Removal’ system. Cleaned ash and we transfer the pellet residues to the ash bin located outside the device. This one so that the ashtray can be used at regular intervals in a more sterilised and hygienic way you can empty it.

    Automatic Ash Extraction

    Thermokoz | Pel (Ash Sticker)
    With the boiler sensor and boiler pump start-up feature, your boiler is now guaranteed to produce hot water in summer and winter! Warm all year round, in all seasons This smart system, which meets your water needs, offers energy efficiency and superior makes your life easier with its performance. Always enjoy hot water Take it out, don't compromise on your comfort!

    Boiler Integration

    Thermokoz | Pel (Ash Sticker)
    What about the electronic board that controls all this equipment? wirelessly control the device, you can control the device fully automatically. manage and set up a weekly programme and automatic work schedule you can create.

    Remote Control

    Thermokoz | Pel (Ash Sticker)
    By rotating the auger with the help of the electronic fuel supply motor It offers the possibility of ‘Automatic Refuelling’. In this way, both from your place You can warm up without getting up and with balanced fuel consumption.

    Automatic Refuelling

    Thermokoz | Pel (Ash Sticker)
    Of course, you do not need to ignite the loaded fuel with your hand. Device fuelling level automatically according to the temperature value you set. will load, then it will take as little as 5 minutes to get it working. in which the ignition will be carried out automatically.

    Automatic Ignition

    Thermokoz | Pel (Ash Sticker)
    Automatic Mixing Our featured hob, 100% efficient combustion provides. Thanks to its innovative design, a powerful and effective warm-up at all times minimises energy losses. High efficiency, maximum Stay one step ahead for performance now!

    Automatic Mixing

    Thermokoz | Pel (Ash Sticker)
    Where does the waste from all these cleared areas go? That's where the answer is given by the ‘Automatic Ash Removal’ system. Cleaned ash and we transfer the pellet residues to the ash bin located outside the device. This one so that the ashtray can be used at regular intervals in a more sterilised and hygienic way you can empty it.

    Automatic Ash Extraction

    Thermokoz | Pel (Ash Sticker)
    With the boiler sensor and boiler pump start-up feature, your boiler is now guaranteed to produce hot water in summer and winter! Warm all year round, in all seasons This smart system, which meets your water needs, offers energy efficiency and superior makes your life easier with its performance. Always enjoy hot water Take it out, don't compromise on your comfort!

    Boiler Integration

    Thermokoz | Pel (Ash Sticker)
    What about the electronic board that controls all this equipment? wirelessly control the device, you can control the device fully automatically. manage and set up a weekly programme and automatic work schedule you can create.

    Remote Control

    Thermokoz | Pel (Ash Sticker)
    By rotating the auger with the help of the electronic fuel supply motor It offers the possibility of ‘Automatic Refuelling’. In this way, both from your place You can warm up without getting up and with balanced fuel consumption.

    Automatic Refuelling

    Thermokoz | Pel (Ash Sticker)
    Of course, you do not need to ignite the loaded fuel with your hand. Device fuelling level automatically according to the temperature value you set. will load, then it will take as little as 5 minutes to get it working. in which the ignition will be carried out automatically.

    Automatic Ignition

    Thermokoz | Pel (Ash Sticker)
    Automatic Mixing Our featured hob, 100% efficient combustion provides. Thanks to its innovative design, a powerful and effective warm-up at all times minimises energy losses. High efficiency, maximum Stay one step ahead for performance now!

    Automatic Mixing

    Thermokoz | Pel (Ash Sticker)
    Where does the waste from all these cleared areas go? That's where the answer is given by the ‘Automatic Ash Removal’ system. Cleaned ash and we transfer the pellet residues to the ash bin located outside the device. This one so that the ashtray can be used at regular intervals in a more sterilised and hygienic way you can empty it.

    Automatic Ash Extraction

    Thermokoz | Pel (Ash Sticker)
    With the boiler sensor and boiler pump start-up feature, your boiler is now guaranteed to produce hot water in summer and winter! Warm all year round, in all seasons This smart system, which meets your water needs, offers energy efficiency and superior makes your life easier with its performance. Always enjoy hot water Take it out, don't compromise on your comfort!

    Boiler Integration

    Thermokoz | Pel (Ash Sticker)
    What about the electronic board that controls all this equipment? wirelessly control the device, you can control the device fully automatically. manage and set up a weekly programme and automatic work schedule you can create.

    Remote Control

    Thermokoz | Pel (Ash Sticker)
    MODEL
    Capacity kW 150
    Width (A) mm 1950
    Length (B) mm 2000
    Height (C) mm 1600
    Cold Water Inlet Height (D) mm 530
    Hot Water Outlet Height (E) mm 1600
    Flue Outlet Height (F) mm 1260
    Flue Diameter mm 250
    Flow – Return inch 2 1/2
    Expansion Tank Outlet inch 1 1/2
    Fill – Drain inch 1/2
    Weight kg 960
    Water Capacity lt 350
    Hopper Capacity lt 230
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 180
    Fan Power W 105
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 230/50
    Operating Current A 16
    Capacity kW 174
    Width (A) mm 2300
    Length (B) mm 2100
    Height (C) mm 1900
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 1900
    Flue Outlet Height (F) mm 1450
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Tank Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1540
    Water Capacity lt 470
    Hopper Capacity lt 450
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 2×105
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 209
    Width (A) mm 2300
    Length (B) mm 2100
    Height (C) mm 2000
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 2000
    Flue Outlet Height (F) mm 1400
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Tank Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1600
    Water Capacity lt 520
    Hopper Capacity lt 450
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 2×105
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 232
    Width (A) mm 2300
    Length (B) mm 2250
    Height (C) mm 2000
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 2000
    Flue Outlet Height (F) mm 1400
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Tank Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1715
    Water Capacity lt 585
    Hopper Capacity lt 450
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 2×105
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 290
    Width (A) mm 2450
    Length (B) mm 2300
    Height (C) mm 2200
    Cold Water Inlet Height (D) mm 650
    Hot Water Outlet Height (E) mm 2200
    Flue Outlet Height (F) mm 1600
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Tank Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 2080
    Water Capacity lt 1050
    Hopper Capacity lt 600
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 2×105
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    <

    Capacity kW 348
    Width (A) mm 2500
    Length (B) mm 2850
    Height (C) mm 2250
    Cold Water Inlet Height (D) mm 720
    Hot Water Outlet Height (E) mm 2250
    Flue Outlet Height (F) mm 1750
    Flue Diameter mm 400
    Flow – Return inch 3
    Expansion Tank Outlet inch 2
    Fill – Drain inch 2
    Weight kg 3000
    Water Capacity lt 1350
    Hopper Capacity lt 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 2×240
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Capacity kW 465
    Width (A) mm 2560
    Length (B) mm 3250
    Height (C) mm 2250
    Cold Water Inlet Height (D) mm 720
    Hot Water Outlet Height (E) mm 2250
    Flue Outlet Height (F) mm 1750
    Flue Diameter mm 400
    Flow – Return inch 3
    Expansion Tank Outlet inch 2
    Fill – Drain inch 2
    Weight kg 3500
    Water Capacity lt 1750
    Hopper Capacity lt 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 2×240
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 581
    Width (A) mm 2800
    Length (B) mm 3550
    Height (C) mm 2550
    Cold Water Inlet Height (D) mm 730
    Hot Water Outlet Height (E) mm 2550
    Flue Outlet Height (F) mm 1950
    Flue Diameter mm 500
    Flow – Return inch 4
    Expansion Tank Outlet inch 2
    Fill – Drain inch 2
    Weight kg 4000
    Water Capacity lt 2500
    Hopper Capacity lt 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 3×240
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 697
    Width (A) mm 2800
    Length (B) mm 4050
    Height (C) mm 2550
    Cold Water Inlet Height (D) mm 730
    Hot Water Outlet Height (E) mm 2550
    Flue Outlet Height (F) mm 1950
    Flue Diameter mm 500
    Flow – Return inch 4
    Expansion Tank Outlet inch 2
    Fill – Drain inch 2
    Weight kg 5550
    Water Capacity lt 3100
    Hopper Capacity lt 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 3×240
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 814
    Width (A) mm 3500
    Length (B) mm 4000
    Height (C) mm 2800
    Cold Water Inlet Height (D) mm 750
    Hot Water Outlet Height (E) mm 2750
    Flue Outlet Height (F) mm 2250
    Flue Diameter mm 600
    Flow – Return inch 5
    Expansion Tank Outlet inch 2 1/2
    Fill – Drain inch 2 1/2
    Weight kg 6000
    Water Capacity lt 3500
    Hopper Capacity lt 1600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 3×240
    Ash Box Capacity l 200
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 930
    Width (A) mm 3500
    Length (B) mm 4250
    Height (C) mm 2800
    Cold Water Inlet Height (D) mm 750
    Hot Water Outlet Height (E) mm 2800
    Flue Outlet Height (F) mm 2250
    Flue Diameter mm 600
    Flow – Return inch 5
    Expansion Tank Outlet inch 2 1/2
    Fill – Drain inch 2 1/2
    Weight kg 6770
    Water Capacity lt 3900
    Hopper Capacity lt 1600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 3×240
    Ash Box Capacity l 200
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Capacity kW 1160
    Width (A) mm 3500
    Length (B) mm 4500
    Height (C) mm 3000
    Cold Water Inlet Height (D) mm 800
    Hot Water Outlet Height (E) mm 3000
    Flue Outlet Height (F) mm 2350
    Flue Diameter mm 600
    Flow – Return inch 5
    Expansion Tank Outlet inch 2 1/2
    Fill – Drain inch 2 1/2
    Weight kg 7500
    Water Capacity lt 4800
    Hopper Capacity lt 1600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Gear Motor Power W 750
    Fan Power W 3×240
    Ash Box Capacity l 200
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 40
    Thermokoz | Pel (Ash Sticker) PDF
    Teknik Resim